EZFloat 6.0

The EZFLOAT 6.0 W Natural series systems have veen formulated for use in the manufacturing of void filling applications, flotation and applications requiring fire retardant properties. EZFLOAT EZF 2502-6.0-W-Natural is Coat Guard Approved for Marine Applications such as lifeboats, rescue boats, life floats and buoyant apparatus. This product meets MIL-P-21929C in accordance with 46 CFR 160.035-3(u)(7) and FR meets MIL-F-83671 3.13

Ideal for shipping out the following:

Containers for both Side-A and Side-B components should be kept tightly closed to prevent moisture contamination. Do not reseal if contamination is suspected. To extend teh chemical's life, the use of a dry nitrogen blanket for partial drums is recommended. Both chemicals may be stored at ambient temperatures (50-95 degrees F). For best results, this product should not be allowed to freeze. Do not breathe aerosol or vapors and avoid contact with skin and eyes. Exposure to vapors of MDI (A-side chemical) heated in an open container can be dangerous.

Appropriate literature is available from the E-ZZ Flow which provides information concerning the health and safety precautions that must be observed when handling any of the products listed above. Before working with these products, it is your responsibility to read and become familiar with the available information on the hazards, proper use and handling. This is extremely important and connot be overemphasized. Information is available in several forms, e.g. safety data sheets and product labels. To obtain this information, contact your E-Z Flow Systems representative.

Physical Properties

Typical Values

Cream Time

40 - 50 seconds

Rise Time

200 - 250 seconds

Demold Time

5 - 20 minutes

Density, pdf

6 lbs/ft3 (96.1 kgs/m3)

Compressive Strength, Parallel

80 psi (0.552 MPa)

Compressive Strength, Perpendicular

55 psi (0.379 MPa)

Shear Strength

70 psi (0.483 MPa)

Closed Cell Content

N/A %

Machine

E-Z Flow Gen IV
Foam-in-Place System

Air Pressure Range
for 2:1 Pumps operation

95-110PSI

Isocyanate (A) side Initial Temperature Setting

120°F

Polyol Resin (B) side
Inital Temperature Setting

140°F

Different temperatures may be required for best results. Consult. your E-Z Flow Representative for optimization. Temperatures above 140°F should be avoided on A-side.


Connect With Us