Clogs in Packaging Foam Systems

There are some common problems and easy solutions with E-Z Flow systems. Fortunately, this is a very simple, easy-to-use machine. Anything you do with this equipment should only take you about ten minutes. However, if you find it’s taking longer, call us. [CM1] 
 
We recommend watching this short video, “Maintenance and Repair” in which trouble shoot maintenance issues.

Most Common Problem and Solution

The single most common issue with packaging foam systems is cartridge clogs. These are usually on the red or “A” side because the isocyanate (“A” chemical) tends to form crystals that block the orifices in the cartridge.
 
The solution to this is to take the cartridge out of the gun – turn both the valve handles to the OFF position, unscrew the knob underneath, make sure the notch on the motor shaft is straight up and down, then just lift the cartridge out. Then, squirt some SLIDE spray solvent (provided when you purchased the system; you should be using about one can of SLIDE for each drum set of chemicals, to keep the gun and cartridge clean) into the little holes on the underside of the cartridge, where the foam comes out.
 
Look to make sure it’s clean (usually, you’ll see a little brown clot of “A” chemical come out of the orifice when you shoot the SLIDE in there), then put the cartridge back in, making sure the little white O-rings are in place, and the “saddle” (where the cartridge fits) is clean, with no foam buildup.
 
A buildup of foam under the cartridge will prevent the cartridge from seating properly, and may lift it high enough that the O-rings will no longer seal, then you’ll get leakage of chemical under the cartridge.
 
Drop the cartridge back in, screw the knob into place to hold the cartridge down firmly, then turn the valves back on and you can continue shooting foam. If the gun is relatively clean, that whole process should take you less than two minutes.
 
Many customers think that the pump is somehow at fault if one side is not coming out properly. The quick way to check that is to turn the valves off; remove the filter nut on the side that isn’t coming out; aim the gun at a waste container; then cautiously open the valve.
 
You should get a good flow of that chemical out the filter well. Then turn off the valve (While the filter nut is off, check it to be sure it isn’t clogged; shoot some SLIDE into it, and around the inside of the filter well) and replace the Filter Nut.
 

Contact Us

If you’d like specific information, please send us the form below. Select the items that apply, and then let us know how to contact you.